Products

Dynamic Strainmeters Analog type Index

Analog type

  • DA-17A
  • DA-17A
    The DA-17A is a carrier wave type dynamic strainmeter with frequency response of 2.5kHz. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system. By installing the units in the exclusive carrying case for computer control, control from a PC via LAN is possible such as setting of sensitivity and low pass filter, operation of balancing and calibration, and acquisition of setting and monitor values.
  • DA-37A
  • DA-37A
    The DA-37A is a carrier wave type dynamic strainmeter with high frequency response of 10kHz. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system. By installing the units in the exclusive carrying case for computer control, control from a PC via LAN is possible such as settings of sensitivity and low pass filter, operation of balancing and calibration, and acquisition of setting and monitor values.
  • DA-18A
  • DA-18A
    The DA-18A is a carrier wave type dynamic strainmeter featuring easy operation and excellent noise resistivity. Digital sensitivity setting method is adopted to enable easy and accurate setting. Also provided is digital display function of measurement value for reliable dynamic measurement. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system. In combination with a TEDS transducer, sensitivity is automatically set.
  • DA-38A
  • DA-37A
    The DA-38A is a carrier wave type dynamic strainmeter with high frequency response of 10kHz. It features easy operation and excellent noise resistivity. Digital sensitivity setting method is adopted to enable easy and accurate setting. Also provided is digital display function of measurement value for reliable dynamic measurement. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system. In combination with TEDS transducer, sensitivity is automatically set.
  • DC-96A/DC-97A
  • DC-96A/DC-97A
    These are DC exciting dynamic strainmeters with high frequency response of 200kHz(DC-96A) and 500kHz(DC-97A). Bridge excitation can be selected between constant voltage and constant current. When using the constant current excitation, there is no sensitivity decrease due to the cable resistance between the strainmeter and the strain gauge type transducers or bridge box. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system.

Page Top