Products
FLM/WFLM series Metal backing strain gauge
This gauge has a thin stainless steel backing which prevents the lowering of insulation resistance caused by the penetration of moisture from the concrete surface. It is suited to long term measurement. The WFLM has integral lead wire and moisture proof coating over the gauge.
|
Applicable specimen
|
Metal, Ceramics,
Composite |
Backing
|
SUS304
|
|
Operational temperature(°C)
|
-20~+80°C
|
Element
|
Ni-Cr
|
|
Temperature compensation range(°C)
|
+10~+80°C
|
Strain limit
|
0.5%
(5000×10-6strain) |
|
Bonding adhesive
|
PS
|
Fatigue life at room temperature
|
1×105
(±1000×10-6strain) |
Detailed material
CONCRETE MATERIAL USE
Single-element (G.F. 2.0 approx.)

|
Type
|
Gauge
length (mm) |
Gauge
width (mm) |
Backing
length (mm) |
Backing
width (mm) |
Backing
thickness (mm) |
Resistance
(Ω) |
|
FLM-30-11
|
30
|
0.5
|
60
|
18
|
0.12 |
120
|
|
FLM-60-11
|
60
|
0.7
|
90
|
18
|
0.12 |
120
|
WATERPROOF TYPE
Single-element (G.F. 2.0 approx.)
0.09mm2 integral crosslinked polyethylene sheath leadwire of 2m standard
Total leadwire resistance per meter : 0.4Ω

|
Type
|
Gauge
length (mm) |
Gauge
width (mm) |
Backing
length (mm) |
Backing
width (mm) |
Backing
thickness (mm) |
Resistance
(Ω) |
|
WLM-30-11
|
30
|
0.5
|
60
|
18
|
4 |
120
|
|
WFLM-60-11
|
60
|
0.7
|
90
|
18
|
4 |
120
|