Products
PMF series Mold strain gauge
This gauge has been designed for measuring interior strain in concrete or mortar under loading test. It employs super engineering plastics capable of superior water proofing characteristics. Its small construction enables installation even in a small specimen. Measurement of both strain and temperature is possible by combining the temperature integrated gauge with TML data logger.
*For long-term period use, Strain Transducer KM should be applied.
|
Applicable specimen
|
Metal, Ceramics,
Composite |
Backing
|
Acryic
|
|
Operational temperature(°C)
|
-20~+60°C
|
Element
|
Cu-Ni (wire)
|
|
Temperature compensation range(°C)
|
|
Strain limit
|
2%
(20000×10-6strain) |
|
Bonding adhesive
|
Embedment
|
Fatigue life at room temperature
|
1×105
(±1000×10-6strain) |
Detailed material
CONCRETE, MORTAR MATERIALS USE
Single-element (G.F. 2.0 approx.)
0.09mm2 integral crosslinked vinyl sheath leadwire of 2m standard
Total leadwire resistance per meter : 0.4Ω

|
Type
|
Gauge
length (mm) |
Gauge
width (mm) |
Backing
length a(mm) |
Backing
width b(mm) |
Backing
thickness c(mm) |
Gauge center d(mm) |
Resistance
(Ω) |
|
PMFL-50-2LT
|
50
|
1
|
60
|
ø8
|
ø4 | 27 |
120
|
|
PMFL-60-2LT
|
60
|
1
|
70
|
ø8
|
ø4 | 32 |
120
|
Temperature Sensor integrated
Single-element (G.F. 2.0 approx.)
0.08mm2 integral vinyl leadwire of 3m standard
Total leadwire resistance per meter : 0.44Ω

|
Type
|
Gauge
length (mm) |
Gauge
width (mm) |
Backing
length a(mm) |
Backing
width b(mm) |
Backing
thickness c(mm) |
Gauge center d(mm) |
Resistance
(Ω) |
|
PMFL-50T-3LT
|
50
|
1
|
60
|
ø8
|
ø4 | 27 |
120
|
|
PMFL-60T-3LT
|
60
|
1
|
70
|
ø8
|
ø4 | 32 |
120
|
These gauges are made to order.