Products

TF series Temperature gauge

This gauge is bonded on the specimen surface like as ordinary strain gauge for the measurement of surface temperature. It can measure not only relative temperature but also actual temperature by using optional temperature gauge adaptor (TGA) together.

Applicable specimen
Metal
Backing
Polyimide
Operational temperature(°C)
-20~+200°C
Element
Ni alloy
Temperature compensation range(°C)
+10~+80°C
Strain limit
Bonding adhesive
CN,NP-50,
C-1
Fatigue life at room temperature

Detailed material

TEMPERATURE GAUGE

Gauge pattern
Type
Sensitivity
(Ω/°C)
Gauge
length
(mm)
Gauge
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Resistance
(Ω)
TFL-2-60
TFL-2-60
0.34
approx.
2
1.9
6.1
3.5
60
TFL-3-60
0.34
approx.
3
3.2
8.5
5.0
60
TFL-6-60
0.34
approx.
6
2.6
13.0
4.5
60
TFL-8
TFL-8
0.68
approx.
8
3.5
14.0
5.4
120
Leadwire-integral service is available on request.

Page Top

TGA-1A/TGA-1B Temperature Gauge Adaptor Optional

This adaptor is provided with temperature gauge TF series for direct reading of temperature with optional strainmeter, and converts output to 100×10-6 strain/°C.

Type of
Adaptor
Type
Temperature
(°C)
Sensitivity
(×10-6strain/°C)
Accuracy
(°C)
Bridge
mode
Dimensions
(W)×(H)×(D)
Weight
(g)
TGA-1A
TFL-2-60
-20~+200°C
100
±1,or less
Full bridge
100×40×70
370
TFL-3-60
TFL-6-60
TGA-1B
TFL-8

Page Top