TF series Temperature gauge

These gauges are bonded on the specimen surface like ordinary strain gauges, and measures the surface temperature. By combining with the dedicated temperature gauge adaptor (TGA-1A or TGA-1B), actual temperature can be measured easily using a strainmeter.

Applicable
specimen
General
Backing
Polyimide
Operational
temperature(°C)
-20 ~ +200°C
Element
Ni alloy
Temperature
compensation range(°C)
-10 ~ +80°C
Strain limit
Applicable adhesive
CN,NP-50B,
C-1
Fatigue life
at room temperature

Detailed material

TEMPERATURE GAUGE

Gauge pattern
Type
Sensitivity
(Ω/°C)
Gauge
length
(mm)
Gauge
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Resistance
(Ω)
TFL-2-60
TFL-2-60
0.34
approx.
2
1.9
6.1
3.5
60
TFL-3-60
0.34
approx.
3
3.2
8.5
5.0
60
TFL-6-60
0.34
approx.
6
2.6
13.0
4.5
60
TFL-8
TFL-8
0.68
approx.
8
3.5
14.0
5.4
120
Leadwire-integral service is available on request.

Page Top

TGA-1A/TGA-1B Temperature Gauge Adaptor Optional

This adaptor is provided with temperature gauge TF series for direct reading of temperature with optional strainmeter, and converts output to 100×10-6 strain/°C.

Type of
Adaptor
Type
Temperature
(°C)
Sensitivity
(×10-6 strain/°C)
Accuracy
(°C)
Bridge
mode
Dimensions
(W)×(H)×(D)
Weight
(g)
TGA-1A
TFL-2-60
-20 ~ +200°C
100
±1,or less
Full bridge
100×40×70
370
TFL-3-60
TFL-6-60
TGA-1B
TFL-8

Page Top