Clip-on Displacement Transducer UB-A

UB-A Clip-on Displacement Transducer
2 / 5 mmCE

The UB-A Displacement Transducer is designed to measure crack opening displacement (COD) in metal.
The shape of the tip conforms to ASTM specifications.

UB-A Clip-on Displacement Transducer
Features
  • The shape of the tip conforms to ASTM standards
  • Specifications

    Type Capacity Rated output Sensitivity
    (x10-6 strain/mm)
    Non-linearity Temperature range
    UB-5A 5 (3 to 8)mm Approx. 2.5 mV/V
    (5000x10-6 strain)
    Approx. 1000 1 %RO 0 to +40 ℃

    Output polarity

    Measurement moves in the plus direction with regard to the direction the gap between the tabs opens in.

Clip-on Displacement Transducer UB

UB Clip-on Displacement Transducer
2 / 5 mmCE

The UB Displacement Transducer is designed to measure crack opening displacement(COD) in metal.

UB Clip-on Displacement Transducer
  • Specifications

    Type Capacity Rated output Sensitivity
    (x10-6 strain/mm)
    Non-linearity Temperature range
    UB-2 2 (2 to 4) mm Approx. 2.5 mV/V
    (5000x10-6 strain)
    Approx. 2500 1 %RO 0 to +40 ℃
    UB-5 5 (2 to 7) mm Approx. 1000

    Output polarity

    Measurement moves in the plus direction with regard to the direction the gap between the tabs opens in.

Clip-on Displacement Transducer RA-L

RA-L Cryogenic Clip-on Displacement Transducer 2 / 5 mm

The RA-L Displacement Transducer is designed to measure crack opening displacement(COD) in metal under low-temperature conditions.

RA-L Cryogenic Clip-on Displacement Transducer
Features
  • Usable in low temperature of -196 ℃
  • Specifications

    Type Capacity Rated output Sensitivity
    (x10-6 strain/mm)
    Non-linearity Temperature range
    RA-2L 2 (2 to 4)mm Approx. 1 mV/V
    (2000x10-6 strain)
    Approx. 1000 1 %RO -196 to +40 ℃
    RA-5L 5 (2 to 7)mm Approx. 1.5 mV/V
    (3000x10-6 strain)
    Approx. 600

    Output polarity

    Measurement moves in the plus direction with regard to the direction the gap between the tabs opens in.

Clip-on Displacement Transducer RA

RA Clip-on Displacement Transducer
2 / 5 mmCE

The RA Displacement Transducer is designed to measure crack opening displacement(COD) in metal.

RA Clip-on Displacement Transducer
  • Specifications

    Type Capacity Rated output Sensitivity
    (x10-6 strain/mm)
    Non-linearity Temperature range
    RA-2 2 (2 to 4)mm Approx. 1 mV/V
    (2000x10-6 strain)
    Approx. 1000 1 %RO 0 to +40 ℃
    RA-5 5 (2 to 7)mm Approx. 1.5 mV/V
    (3000x10-6 strain)
    Approx. 600

    Output polarity

    Measurement moves in the plus direction with regard to the direction the gap between the tabs opens in.

Arrester NZ-7C

Arrester NZ-7C

An arrester protects measuring instruments and transducers from induced lighting. In lighting-prone areas, the induced voltage of lighting traveling through the cables of measuring instruments or switch boxes can damage instruments and transducers. When placing measuring instruments and transducers, connection of NZR-7B/NZ-7C on cabling between an instrument and a switch box or NZ-6B on cabling between a transducer and switch box will protect the instrument and transducer by allowing induced current to pass to the ground.

Arrester NZ-7C
Features
  • Either soldering or NDIS plug is possible for cable connection
  • Contains a commercial power supply (built-in varistor) terminal, allowing power supply for a switch box to be connected easily
  • Specifications

    Type NZ-7C
    Applicable instruments Data logger: TDS-630, TDS-540, TDS-530
    Switching Box: ASW-50C, ASW-30C, SSW-50D
    Surge resistance (8/20µs)
    Between bridges: 442A
    Between bridge and ground: 10kA
    Between F and ground: 442A
    Between G and ground: 442A
    Dimensions 290 (W) x 62(H) x 101 (D) mm
    Weight Approx. 1.3kg

Arrester NZR-7B

Arrester NZR-7B

An arrester protects measuring instruments and transducers from induced lighting. In lighting-prone areas, the induced voltage of lighting traveling through the cables of measuring instruments or switch boxes can damage instruments and transducers. When placing measuring instruments and transducers, connection of NZR-7B/NZ-7C on cabling between an instrument and a switch box or NZ-6B on cabling between a transducer and switch box will protect the instrument and transducer by allowing induced current to pass to the ground.
end of production

Arrester NZR-7B
Features
  • While a measuring instrument is on standaby, NZR-7B automatically separates the circuit between all instruments with a high-voltage relay to block induced current
  • Either soldering or NDIS plug is possible for cable connection
  • Specifications

    Type NZR-7B
    Applicable instruments Data logger: TDS-630, TDS-540, TDS-530
    Switching Box: ASW-50C, ASW-30C, SSW-50D
    Surge resistance (8/20µs)
    Between bridges: 442A between bridge
    Between bridge and ground: 10kA
    Between F and ground: 10kA
    Between G and ground: 10kA
    Dimensions 290 (W) x 64 (H) x 101 (D) mm
    Weight Approx. 1.4kg

High Temperature Weldable Strain Gauge AWC-8B Quarter bridge with 3-wire method (G.F. 2.1 approx.)

AWC-8B Quarter bridge with 3-wire method (G.F. 2.1 approx.)

These strain gauges have hermetically sealed construction with the sensing element encapsulated in the stainless steel tube. This construction helps to simplify the coatings for moisture and water proofing, and the strain gauges are suited to strain measurement for long term and/or in harsh environment.

Main object material Metal
Operational temperature -20 to +100℃
Temperature compensation range AWC-8B: +10 to +100℃
Bonding adhesive Spot welding (TML spot welder W-50R is required)
Backing SUS304
Element Special alloy
Strain limit 0.5% (5000 x 10-6 strain)
Fatigue life at room temperature 1 x 106 (±1000 x 10-6 strain)