KCE-NA Center-hole type Compression Load Cell 500kN to 2MN
The KCE-NA Load Cell is a center-hole-type load cell designed to use in tension measurement of anchoring strand. It can deliver stable measurement performance under somewhat eccentric load. An extra model with built-in temperature sensor is available.
Protection ratings : IP 67 equivalent.
- Features
- Splash-proof structure
- Small effect of eccentric load
-
Specifications
Type |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
KCE-500KNA |
500 kN |
1.25 mV/V
(2500x10-6 strain) ±10 % |
0.5 %RO |
-20 to +70 ℃ |
KCE-1MNA |
1 MN |
KCE-1.5MNA |
1.5 MN |
KCE-2MNA |
2 MN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
Flat Compression Load Cell
High capacity Acceleration Transducer ARE-A-T
ARE-A-T High capacity Tri-axial Acceleration Transducer 1000 to 5000m/s2
This compact and high-capacity acceleration transducer combines each of the 3 component directions in its casing, allowing simultaneous measurement of acceleration in 3 directions.
Protection ratings : IP 61 equivalent
- Features
- Simultaneous measurement in 3 directions
- Less mutual interference
- Easy to install
-
Specifications
Type |
Capacity |
Rated output |
Non-linearity |
Temperature range |
ARE-1000A-T |
1000 m/s2 |
Approx. 0.5 mV/V
(1000x10-6 strain) |
1 %RO |
-10 to +50 ℃ |
ARE-2000A-T |
2000 m/s2 |
ARE-5000A-T |
5000 m/s2 |
-10 to +60 ℃ |
Output polarity
Measurement moves in the plus direction when acceleration occurs in the acceleration transducer itself toward the “+” mark on the casing.
High capacity Acceleration Transducer ARE-A
ARE-A High capacity Acceleration Transducer 1000 to 10000m/s2
The ARE-A acceleration transducer is used to measure the acceleration of structures subject to relatively strong vibration. It is small, lightweight and easy to operate.
Protection ratings : IP 61 equivalent
-
Specifications
Type |
Capacity |
Rated output |
Non-linearity |
Temperature range |
ARE-1000A |
1000 m/s2 |
Approx. 0.5 mV/V
(1000x10-6 strain) |
1 %RO |
-10 to +50 ℃ |
ARE-2000A |
2000 m/s2 |
ARE-5000A |
5000 m/s2 |
-10 to +60 ℃ |
ARE-10000A |
10000 m/s2 |
Output polarity
Measurement moves in the plus direction when acceleration occurs in the acceleration transducer itself toward the “+” mark on the casing.
High capacity Acceleration Transducer
Flat Compression Load Cell CLH-NA
CLH-NA Compression Load Cell 1MN to 2MN
The CLH-NA is designed mainly to test a cylindrical test specimen made of high-strength concrete.The cylindrical specimen can be directly set on the top of load cell. Also, by using the load cell together with a compressometer, it is possible to measure load and strain simultaneously.
Protection ratings : IP 65 equivalent
- Features
- Guide marking for right placement of specimens with different sizes.
- Easy handling
-
Specifications
Type |
Applicable
specimen |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
CLH-1MNA |
Φ10×20 cm |
1MN |
1.5 mV/V
(3000×10-6 strain) ±0.5% |
0.2 %RO |
-20 to +70 ℃ |
CLH-1.5MNA |
Φ12.5×25 cm |
1.5MN |
CLH-2MNA |
Φ15×30 cm |
2MN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
Flat Compression Load Cell CLL-NA
CLL-NA Compression Load Cell
500kN to 1MN 
The CLL-NA load cells with a flat loading platform are used to conduct loading tests on cylindrical concrete specimens. A cylindrical concrete specimen can be directly set on the surface of the loading platform. By using this load cell together with the compressometer, it is possible to measure load and strain simultaneously.
Protection ratings : IP 65 equivalent
- Features
- Guide marking for right placement of specimens with different sizes
- Easy handling
-
Specifications
Type |
Applicable
specimen |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
CLL-500KNA |
Φ10×20 cm |
500kN |
1.5mV/V
(3000×10-6 strain) ±0.5 % |
0.2 %RO |
-20 to +70 ℃ |
CLL-1MNA |
Φ15×30 cm |
1MN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
High-precision Compression Load Cell
High-precision Compression Load Cell CLJ-NB
CLJ-NB Compression Load Cell 50kN to 10MN
CLJ-NBThe CLJ-NB Load Cell is designed considering JIS B 7728 "Load calibration devices for verifying material testing machine" and is the most suitable for verification of single axis compression testing machine. Calibration in accordance with JIS B 7728 is available at extra cost.
Protection ratings : IP 67 equivalent
- Features
- High Precision (0.05 %RO Non-linearity)
- Compatible with remote sensing
-
Specifications
Type |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
CLJ-50KNB |
50kN |
2 mV/V
(4000×10-6 strain) or more |
0.05 %RO |
-20 to +70 ℃ |
CLJ-100KNB |
100kN |
CLJ-200KNB |
200kN |
CLJ-300KNB |
300kN |
CLJ-500KNB |
500kN |
CLJ-1MNB |
1MN |
CLJ-2MNB |
2MN |
CLJ-3MNB |
3MN |
CLJ-5MNB |
5MN |
CLJ-10MNB |
10MN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
High-precision Compression Load Cell CLJ-NA
CLJ-NA Compression Load Cell 5kN to 30kN
CLJ-NAThe CLJ-NA Load Cell is designed considering JIS B 7728 "Load calibration devices for verifying material testing machine" and is the most suitable for verification of single axis compression testing machine. Calibration in accordance with JIS B 7728 is available at extra cost.
Protection ratings : IP 65 equivalent
- Features
- High Precision
- Compatible with remote sensing
-
Specifications
Type |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
CLJ-5KNA |
5kN |
2 mV/V
(4000×10-6 strain) or more |
0.05 %RO |
-30 to +80 ℃ |
CLJ-10KNA |
10kN |
CLJ-20KNA |
20kN |
CLJ-30KNA |
30kN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.