Waterproof strain gauge

WF series Waterproof strain gaugeCE

This is WF-series water proof type strain gauge having a pre-attached vinyl lead wire and an entire coating with epoxy resin. The coating is transparent and flexible, which ensures easy installation of the gauge.

WF series Waterproof strain gauge
Applicable specimen Metal, Glass, Ceramics
Operational temperature(℃) 0 to +80℃
Temperature compensation range(℃) +10 to +80℃
Applicable adhesive CN, P-2
Backing Epoxy
Element Cu-Ni
Strain limit 3% (30000 x 10-6 strain)
Fatigue life at room temperature 3 x 104 (±1500 x 10-6 strain)
  • Single-element (G.F. 2.1 approx.)

    0.08mm2 integral vinyl leadwire Total leadwire resistance per meter : 0.44Ω

    wfla
    Type Gauge Backing Resist-ance
    (Ω)
    Lead wire pre-attached Type name of lead wire preattached
     length
    (mm)
     width
    (mm)
    length
    (mm)
    width
    (mm)
    thickness
    (mm)
    WFLA-3-11
    WFLA-3-17
    WFLA-3-23
    3 1.7 17 8 1.5 120 Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    3-wire 5m
    -1LDBB
    -3LDBB
    -5LDBB
    -3LDBTB
    -5LDBTB
    WFLA-3-350-11
    WFLA-3-350-17
    WFLA-3-350-23
    3 3.2 17 8 1.5 350 Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    -1LDBB
    -3LDBB
    -5LDBB
    WFLA-6-11
    WFLA-6-17
    WFLA-6-23
    6 2.2 25 11 1.5 120 Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    3-wire 5m
    -1LDBB
    -3LDBB
    -5LDBB
    -3LDBTB
    -5LDBTB

    Each package contains 10 gauges.

  • 90° 2-element Rosette Stacked type(G.F. 2.1 approx.)

    0.08mm2 integral vinyl leadwire Total leadwire resistance per meter : 0.44Ω

    wfca
    Type Gauge Backing Resist-ance
    (Ω)
    Lead wire pre-attached Type name of lead wire preattached
    length
    (mm)
    width
    (mm)
    length
    (mm)
    width
    (mm)
    thickness
    (mm)
    WFCA-3-11
    WFCA-3-17
    WFCA-3-23
    3 1.7 19 16 1.5 120 Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    -wire 5m
    -1LDBB
    -3LDBB
    -5LDBB
    -3LDBTB
    -5LDBTB
    WFCA-6-11
    WFCA-6-17
    WFCA-6-23
    6 2.3 25 21 1.5 120 Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    3-wire 5m
    -1LDBB
    -3LDBB
    -5LDBB
    -3LDBTB
    -5LDBTB

    Each package contains 10 gauges.

  • 45°/90°3-element Rosette Stacked type (G.F. 2.1 approx.)

    0.08mm2 integral vinyl leadwire Total leadwire resistance per meter : 0.44Ω

    wfra
    Type Gauge Backing Resist-ance
    (Ω)
    Lead wire pre-attached Type name of lead wire preattached
    length
    (mm)
    width
    (mm)
    length
    (mm)
    width
    (mm)
    thickness
    (mm)
    WFRA-3-11
    WFRA-3-17
    WFRA-3-23
    3 1.7 19 16 1.5 120 Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    3-wire 5m
    -1LDBB
    -3LDBB
    -5LDBB
    -3LDBTB
    -5LDBTB
    WFRA-6-11
    WFRA-6-17
    WFRA-6-23
    6 2.3 25 21 1.5 120 Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    3-wire 5m
    -1LDBB
    -3LDBB
    -5LDBB
    -3LDBTB
    -5LDBTB

    Each package contains 10 gauges.

General Use Strain Gauge F series Foil strain gauge

F series Foil strain gaugeCE

These gauges employ Cu-Ni alloy foil for the grid and special plastics for the backing.  A wide range of operating temperature from -196 to +150°C is possible.  The backing is color coded to identify the objective material for self-temperature compensation.  Strain gauges for stress concentration measurement and residual stress measurement are available in addition to general use gauges.  Leadwire integrated strain gauges are also available with various types of leadwires.  Strain gauges in this series can be supplied with option –F using lead-free solder.  (GOBLET gauges in this series use lead-free solder as standard specifications.)

F series general use
Applicable specimen Metal, Glass, Ceramics
Operational temperature -196 to +150℃
Temperature compensation range +10 to +100℃
Applicable adhesive CN, P-2, EB-2
Backing Special plastics
Element Cu-Ni
Strain limit 5% (50000 x 10-6 strain)
Fatigue life at room temperature 1 x 106 (±1500 x 10-6 strain)
  • For general measurement  Single-element / two-element / three-element

     Single-element (G.F. 2.1 approx.)

    Gauge pattern Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance (Ω)
    flg_111 FLG-02-11
    FLG-02-17
    FLG-02-23
    0.2 1.4 3.5 2.5 120
    FLG-1-11
    FLG-1-17
    FLG-1-23
    1 1.1 6.5 2.5 120
    fla_311 FLA-03-11
    FLA-03-17
    FLA-03-23
    0.3 1.4 3 2.0 120
    FLA-05-11
    FLA-05-17
    FLA-05-23
    0.5 1.2 5 2.2 120
    FLA-1-11
    FLA-1-17
    FLA-1-23
    1 1.3 5 2.5 120
    FLA-1-350-11
    FLA-1-350-17
    FLA-1-350-23
    1 2 4.7 3.6 350
    FLA-2-11
    FLA-2-17
    FLA-2-23
    2 1.5 6.5 3 120
    FLA-2-350-11
    FLA-2-350-17
    FLA-2-350-23
    2 1.9 6.1 3.5 350
    FLA-3-11
    FLA-3-17
    FLA-3-23
    3 1.7 8.8 3.5 120
    FLA-3-60-11
    FLA-3-60-17
    FLA-3-60-23
    3 1.2 8 3 60
    FLA-3-350-11
    FLA-3-350-17
    FLA-3-350-23
    3 3.2 8.5 5 350
    FLA-5-11
    FLA-5-17
    FLA-5-23
    5 1.5 10 3 120
    FLA-5-350-11
    FLA-5-350-17
    FLA-5-350-23
    5 1.8 9.4 3.8 350
    FLA-6-11
    FLA-6-17
    FLA-6-23
    6 2.2 12.5 4.3 120
    FLA-6-1000-11
    FLA-6-1000-17
    FLA-6-1000-23
    6 4.6 13.7 7 1000
    FLA-10-11
    FLA-10-17
    FLA-10-23
    10 2.5 16.7 5 120
    FLA-30-11
    FLA-30-17
    FLA-30-23
    30 2 36.1 5.1 120
    flk_611 FLK-1-11
    FLK-1-17
    FLK-1-23
    1 0.7 4.5 1.4 120
    FLK-2-11
    FLK-2-17
    FLK-2-23
    2 0.9 5.5 1.5 120
    FLK-6-11
    FLK-6-17
    FLK-6-23
    6 1 11.2 2.2 120
    FLK-10-11
    FLK-10-17
    FLK-10-23
    10 1.6 16.2 3.8 120

    Each package contains 10 strain gauges.

     

    2-element 0°/90° Stacked type: FCA, Plane type: FCB(G.F. 2.1 approx.)

    Gauge pattern Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance (Ω)
    fca_211   FCA-1-11
    FCA-1-17
    FCA-1-23
    1 0.7 Φ4.5 120
    FCA-1-350-11
    FCA-1-350-17
    FCA-1-350-23
    1 1.6 Φ8 350
    FCA-2-11
    FCA-2-17
    FCA-2-23
    2 0.9 Φ7 120
    FCA-2-350-11
    FCA-2-350-17
    FCA-2-350-23
    2 1.9 Φ9.5 350
    FCA-3-11
    FCA-3-17
    FCA-3-23
    3 1.7 Φ11 120
    FCA-3-350-11
    FCA-3-350-17
    FCA-3-350-23
    3 2 Φ10 350
    FCA-5-11
    FCA-5-17
    FCA-5-23
    5 1.9 Φ12 120
    FCA-5-350-11
    FCA-5-350-17
    FCA-5-350-23
    5 1.8 Φ10 350
    FCA-6-11
    FCA-6-17
    FCA-6-23
    6 2.4 Φ14 120
    FCA-10-11
    FCA-10-17
    FCA-10-23
    10 2.5 Φ17 120

    Each package contains 10 strain gauges.

     

    3-element 0°/45°/90° Rosette Stacked type (G.F. 2.1 approx.)

    Gauge pattern Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance (Ω)
    fra_211   FRA-1-11
    FRA-1-17
    FRA-1-23
    1 0.7 Φ4.5 120
    FRA-1-350-11
    FRA-1-350-17
    FRA-1-350-23
    1 1.6 Φ8 350
    FRA-2-11
    FRA-2-17
    FRA-2-23
    2 0.9 Φ7 120
    FRA-2-350-11
    FRA-2-350-17
    FRA-2-350-23
    2 1.9 Φ9.5 350
    FRA-3-11
    FRA-3-17
    FRA-3-23
    3 1.7 Φ11 120
    FRA-3-350-11
    FRA-3-350-17
    FRA-3-350-23
    3 2 Φ10 350
    FRA-5-11
    FRA-5-17
    FRA-5-23
    5 1.9 Φ12 120
    FRA-5-350-11
    FRA-5-350-17
    FRA-5-350-23
    5 1.8 Φ10 350
    FRA-6-11
    FRA-6-17
    FRA-6-23
    6 2.4 Φ14 120
    FRA-10-11
    FRA-10-17
    FRA-10-23
    10 2.5 Φ17 120

    Each package contains 10 strain gauges.

  • GLASS/CERAMIC MATERIALS

    Gauge pattern Type Gauge length
    (mm)
    Gauge width
    (mm)
    Backing length
    (mm)
    Backing width
    (mm)
    Resistance (Ω)
    Single-element (G.F. 2.1 approx.)fla_58   FLA-2-8 2 1.5 6.5 3 120
    FLA-5-8 5 1.5 10 3 120
    90° 2-element Rosette (G.F. 2.1 approx.) Stacked typefca_28   FCA-2-8 2 0.9 Φ7 120
    FCA-5-8 5 1.9 Φ12 120
    45°/90° 3-element Rosette (G.F. 2.1 approx.) Stacked typefra_58   FRA-2-8 2 0.9 Φ7 120
    FRA-5-8 5 1.9 Φ12 120

    Each package contains 10 strain gauges.

  • RESIDUAL STRESS MEASUREMENT

    Gauge pattern Type Gauge length (mm) Gauge width (mm) Backing length
    (mm)
    Backing width
    (mm)
    Resistance (Ω) Gauge center diameter (mm)
    fr_5 FR-5-11
    FR-5-17
    FR-5-23
    5 1.5 Φ12.0 120 -
    eubc_06 EUBC-06-11
    EUBC-06-17
    EUBC-06-23
    0.6 0.7 Φ2.4 120 -
    3-element (G.F.2.1 approx.)fras_211   FRAS-2-11
    FRAS-2-17
    FRAS-2-23
    2 1.1 9 9 120 Φ7.0
    frs_311 FRS-08-11
    FRS-08-17
    FRS-08-23
    0.8 0.7 Φ7.0 120 Φ2.56
    FRS-2-11
    FRS-2-17
    FRS-2-23
    1.5 1.3 Φ9.5 120 Φ5.14
    FRS-3-11
    FRS-3-17
    FRS-3-23
    3 2.6 Φ17.5 120 Φ10.26

    Option -F (lead-free solder is used: with CE mark) available
    Each package contains 10 strain gauges.

  • SHEARING STRAIN MEASUREMENT

    Gauge pattern Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance (Ω)
    flt_05a FLT-05A-11
    FLT-05A-17
    FLT-05A-23
    0.55 0.66 4.0 1.3 120
    flt_05b FLT-05B-11
    FLT-05B-17
    FLT-05B-23
    0.55 0.66 4.0 1.3 120

    Option -F (lead-free solder is used: with CE mark) available
    Each package contains 10 strain gauges.

  • TORQUE MEASUREMENT

    Gauge pattern Type Gauge length (mm) Gauge width (mm) Backing length
    (mm)
    Backing width
    (mm)
    Resistance (Ω)
    90° 2-element Rosette, Plane type (G.F. 2.1 approx.)fct_211   FCT-2-11
    FCT-2-17
    FCT-2-23
    2 1.5 8.7 6.5 120
    FCT-2・350-11
    FCT-2・350-17
    FCT-2・350-23
    2 1.5 7.6 5.3 350

    Option -F (lead-free solder is used: with CE mark) available
    Each package contains 10 strain gauges.

  • 2-element 0°/90° plane type

    Gauge pattern Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    mm)
    Backing
    width
    (mm)
    Resistance (Ω)
    fcb_211 FCB-2-11
    FCB-2-17
    FCB-2-23
    2 1.5 8.2 8 120
    FCB-6-350-11
    FCB-6-350-17
    FCB-6-350-23
    6 2 10 11.9 350

    Option -F (lead-free solder is used: with CE mark) available
    Each package contains 10 strain gauges.

  • STRESS CONCENTRATION MEASUREMENT

    Gauge
    pattern
    Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance (Ω) Gauge
    leads
    gauge
    pitch
    5-element single axis X-axis direction (G.F.2.1 approx.)fxv_111002le   FXV-1-11-002LE
    FXV-1-17-002LE
    FXV-1-23-002LE
    1 1.3 5 12 120 Polyimide 2 cm pre-attached 2 mm
    fbxv_0411005le FBXV-04-11-005LE 0.4 1.3 5.4 7.4 120 Polyimide 5 cm pre-attached 1 mm
    5-element single axis Y-axis direction (G.F.2.1 approx.)fyv_111002le   FYV-1-11-002LE
    FYV-1-17-002LE
    FYV-1-23-002LE
    1 1.4 5 12 120 Polyimide 2 cm pre-attached 2 mm
    fbyv_0611005le FBYV-06-11-005LE 0.6 0.8 5.3 7 120 Polyimide 5 cm pre-attached 1 mm
    10-element 2 axes X-axis and Y-axis direction (G.F.2.1 approx.)fcv_111005le   FCV-1-11-005LE
    FCV-1-17-005LE
    FCV-1-23-005LE
    1 1.4 7.5 12 120 Polyimide 5 cm pre-attached 2 mm
    10-element single axis X-axis directionccfxx_1   CCFXX-1ccfxx_1l   1 1.5 4.5 16.4 120 - 1.5 mm
    10-element single axis Y-axis directionccfyx_1   CCFYX-1ccfyx_1l   1 1.5 4.5 16.4 120 - 1.5 mm

    Option -F (lead-free solder is used: with CE mark) available
    Each package contains 10 strain gauges.

    Gauge pattern Type Gauge length (mm) Gauge width (mm) Backing length (mm) Backing width (mm) Resistance (Ω)
    fbx_0411005le
    Polyimide 5 cm pre-attached
    FBX-04-11-005LE 0.4 1.3 5.4 1 120
    fby_0611005le
    Polyimide 5 cm pre-attached
    FBY-06-11-005LE 0.6 0.8 5.3 1 120
    flx_111002le flx_1350002le_0
    Polyimide 2 cm pre-attached
    FLX-1-11-002LE
    FLX-1-17-002LE
    FLX-1-23-002LE
    1 1.3 5 2 120
    FLX-1-350-11-002LE
    FLX-1-350-17-002LE
    FLX-1-350-23-002LE
    1 1.3 5.5 3 350

    Option -F (lead-free solder is used: with CE mark) available
    Each package contains 10 strain gauges.

  • Dedicated integral leadwire recommended for F series

    For general measurement  Single-element / two-element / three-element

    For general use

    Application Product name Lead wire code Applicable temperature of leadwire (℃) Example of type name
    General use (without temperature change) Paralleled vinyl LJB -20 to +80 FLA-5-11-3LJB
    Paralleled vinyl LJC FLA-5-11-3LJC
    General use 3-wire paralleled vinyl LJBT -20 to +80 FLA-5-11-3LJBT
    3-wire paralleled vinyl LJCT FLA-5-11-3LJCT
    Middle - high temperature 3-wire paralleled vinyl LXT -20 to +150 FLA-5-11-3LXT
    Temperature-integrated 3-wire paralleled vinyl TLJBT -20 to +80 FLA-5T-11-3TLJBT
    1-gauge 4-wire Polypropylene 4-wire paralleled (modular plug attached) LQM -20 to +100 FLA-5-11-3LQM

     

    Special use (Torque, Stress concentration measurement)

    Application Product name Lead wire code Applicable temperature of leadwire (℃) Example of type name
    General use (without temperature change) Paralleled vinyl LJB/LJB-F -20 to +80 FLA-5-11-3LJB
    General use 3-wire paralleled vinyl LJBT/LJBT-F -20 to +80 FLA-5-11-3LJBT
    Middle - high temperature 3-wire paralleled vinyl LXT/LXT-F -20 to +150 FLA-5-11-3LXT
    1-gauge 4-wire Polypropylene 4-wire paralleled (modular plug attached) LQM/LQM-F -20 to +100 FLA-5-11-3LQM
  • Standard leadwire integrated strain gauge

    Strain gauges with paralleled vinyl leadwire or 3-wire paralleled vinyl lead wire are available as standard products for F series.

    Single-element

    Used leadwire: 0.11 mm2 Total resistance of leadwire per meter: 0.32 Ω

    fla_611_lead

    Type Gauge length (mm) Gauge width (mm) Backing length (mm) Backing width (mm) Resistance (Ω) Lead wire pre-attached Type name of lead wire preattached
    FLA-1-11
    FLA-1-17
    FLA-1-23
    1 1.3 5 2.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC
    -3LJC
    -5LJC
    -3LJCT
    -5LJCT
    FLA-2-11
    FLA-2-17
    FLA-2-23
    2 1.5 6.5 3 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC
    -3LJC
    -5LJC
    -3LJCT
    -5LJCT
    FLA-3-11
    FLA-3-17
    FLA-3-23
    3 1.7 8.8 3.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC
    -3LJC
    -5LJC
    -3LJCT
    -5LJCT
    FLA-5-11
    FLA-5-17
    FLA-5-23
    5 1.5 10 3 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC
    -3LJC
    -5LJC
    -3LJCT
    -5LJCT
    FLA-6-11
    FLA-6-17
    FLA-6-23
    6 2.2 12.5 4.3 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC
    -3LJC
    -5LJC
    -3LJCT
    -5LJCT

    Minimum order quantity is 10 gauges.

     

    2-element 0°/90° rosette

    Used leadwire: 0.08 mm2 Total resistance of leadwire per meter: 0.44 Ω

    fca_511_lead

    Type Gauge length
    (mm)
    Gauge
    width (mm)
    Backing (mm) Resistance (Ω) Lead wire pre-attached Type name of lead wire preattached
    FCA-1-11
    FCA-1-17
    FCA-1-23
    1 0.7 Φ4.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FCA-2-11
    FCA-2-17
    FCA-2-23
    2 0.9 Φ7 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FCA-3-11
    FCA-3-17
    FCA-3-23
    3 1.7 Φ11 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FCA-5-11
    FCA-5-17
    FCA-5-23
    5 1.9 Φ12 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FCA-6-11
    FCA-6-17
    FCA-6-23
    6 2.4 Φ14 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FCA-10-11
    FCA-10-17
    FCA-10-23
    10 2.5 Φ17 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT

    Minimum order quantity is 10 gauges.

     

    3-element 0°/45°/90° rosette

    Used leadwire: 0.08 mm2 Total resistance of leadwire per meter: 0.44 Ω

    FRA

    Type Gauge length
    (mm)
    Gauge
    width (mm)
    Backing (mm) Resistance (Ω) Lead wire pre-attached Type name of lead wire preattached
    FRA-1-11
    FRA-1-17
    FRA-1-23
    1 0.7 Φ4.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FRA-2-11
    FRA-2-17
    FRA-2-23
    2 0.9 Φ7 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FRA-3-11
    FRA-3-17
    FRA-3-23
    3 1.7 Φ11 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FRA-5-11
    FRA-5-17
    FRA-5-23
    5 1.9 Φ12 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FRA-6-11
    FRA-6-17
    FRA-6-23
    6 2.4 Φ14 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT
    FRA-10-11
    FRA-10-17
    FRA-10-23
    10 2.5 Φ17 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB
    -3LJB
    -5LJB
    -3LJBT
    -5LJBT

    Minimum order quantity is 10 gauges.

Small Multi-channel Data Acquisition System MULTI RECORDER TMR-300 Series

見出し

Small Multi-channel Data Acquisition System MULTI RECORDER TMR-300 Series

概要

Multi-recorder TMR-300 series is a compact multi-channel data acquisition system capable of combining measurement units for inputting various sensors according to the purpose of measurement. Due to its compact size and light weight, the system can be easily installed not only on existing structures such as machines and bridges in which the installation space is restricted, but also on moving bodies such as automobiles, aircrafts and ships. One control unit and ten measurement units can be connected together and placed in a small space, or each measurement unit can be distributed in the vicinity of the sensors to be measured.

画像