High-capacity, Low-profile Tension/Compression Load Cell

TCLY-NA Tension/Compression Load Cell 300kN to 10MNCE

The TCLY-NA is a Tension/Compression Universal Load Cell with low-profile construction and high-capacity. It offers high precision, high output characteristics and an excellent stability because it uses a shear beam for the strain sensing element. This model is widely used in applications like uni-axial testing machine.

Protection ratings : IP40 equivalent

TCLY-NA Tension/Compression Load Cell
Features
  • High precision,High output
  • Specifications

    Type Capacity Rated output Non-linearity Temperature
    range
    TCLY-300KNA 300kN 2mV/V
    (4000×10-6 strain)±0.5%
    0.2%RO -10 to +60 ℃
    TCLY-500KNA 500kN
    TCLY-1MNA 1MN
    TCLY-1.5MNA 1.5MN
    TCLY-2MNA 2MN
    TCLY-5MNA 5MN Made-to-order
    Contact us for details.
    TCLY-10MNA 10MN

    Output polarity

    Measurement moves in the plus direction with regard to increased tensile force, and in the minus direction with regard to increased compressing force.

Strain Checker

Strain Checker FGMH Series
(Frictional strain gauge)CE

Conventional strain gauges pick up strain on the structures through adhesive layers. On the contrary, the strain checker picks up strain through friction by pressing down the strain sensing element on the structure with the magnet.  The strain checker can be easily fixed on the position of interest and immediately get ready for strain measurement.  The FGMH-1B/FGMH-4A is a standard type with small and light construction. The FGMH-2A is for measurement in a narrow space, such as a side of a welded part.  The FGMH-3A has 3-element 45° / 90° rectangular rosette configuration capable of measuring strains in 3 axes and obtaining principal stress (principal strain) by rosette analyses.

FGMH-1B
FGMH-1B
FGMH-2A
FGMH-2A
FGMH-2A
FGMH-2A
FGMH-3A
FGMH-3A
FGMH-4A
FGMH-4A

 

Features
  • Adopting friction
    Adheres to the object with magnet and picks up strain by means of friction generated on the contact surface.
  • No need of adhesive
    Installation procedures of conventional strain gauges such as removing paint, grinding, degreasing, bonding and curing are not required. Measurement is available immediately after attaching the strain checker.
  • No need of paint restoration after measurement
    It is not necessary to restore the paint after the measurement, because the measurement is made without removing the paint.
  • Enables to use repeatedly
    Measurement point can be easily moved because the strain checker is easily attached and detached. It is possible to find the most strained point by moving the strain checker like as a stethoscope, using a DH-14A as a strain reading instrument.
  • Multiple simultaneous measurement
    Simultaneous measurement of multiple points is possible by using two or more strain checkers. Strain distribution and principal stress direction can be obtained.

 

checker_appl

  • Specifications

    Type FGMH-1B FGMH-2A FGMH-3A FGMH-4A
    Number of axes Single(1) 3 Single
    Gauge length 6mm 3mm 3mm or 6mm
    Allowable temperature range 0 to +60℃
    Gauge factor Approx. 2
    Input/output resistance Approx.120Ω
    Measurement mode Full bridge
    Supplied cable - Φ3mm 0.05mm2
    4-core shielded chloroprene cable 2m with NDIS-plug
    3- Φ3mm 0.05mm2
    4-core shielded chloroprene cable with a connector plug
    -
    Supplied cable 2m with bridge circuit board with NDIS plug - Φ3mm 0.05mm2
    4-core shielded chloroprene cable 2m with NDIS-plug
    (Type : FGL-2B)
    Weight Approx. 60g (excluding cable) Approx. 260g (excluding cable) Approx. 30g

Ultracompact Compression Load Cell

CLS-NA/CLS-NB Compression Load Cell 2N to 10kNCE

The CLS-NA and CLS-NB Load Cells are ultracompact load cells with capacities ranging from 2N to 10kN. They are widely used for measuring load distribution or loads in structural mock-up testing and as a sensor for industrial machinery.

CE marking. : CLS-NB

Protection ratings
: IP 53 equivalent / IP 41 equivalent(CLS-2NA , CLS-5NA)

Ultracompact Compression Load Cell
Features
  • Smallest ø12 mm, lightest 1 g
  • Miniature, High accuracy, High sensitivity
  • Easy handling
  • Ideal sensor for model testing
  • Specifications

    Type Capacity Rated output Non-linearity Temperature
    range
    CLS-2NA 2N 1mV/V
     (2000x10-6 strain)±30%
    1%RO -10 to +60℃
    CLS-5NA 5N
    CLS-10NA 10N 1mV/V
     (2000x10-6 strain)±20%
    0.5%RO
    CLS-20NA 20N
    CLS-50NA 50N
    CLS-100NA 100N
    CLS-200NB 200N 1.5mV/V
     (3000x10-6 strain)±10%
    CLS-500NB 500N
    CLS-1KNB 1kN
    CLS-2KNB 2kN
    CLS-5KNB 5kN
    CLS-10KNB 10kN

    Output polarity

    Measurement moves in the minus direction with regard to increased compressing force.

High and low temperature strain gauge

CEF series
High and low temperature strain gauge

CEF series high and low temperature strain gauges utilize polyimide resin for the backing and a special alloy for the element. They feature a wide range of operating temperature from −269 to +200°C.

High and low temperature strain gauge
Applicable specimen Metal, Ceramics
Operational temperature(℃) -269 to +200℃
Temperature compensation range(℃) -196 to +80℃
Applicable adhesive C-1, EA-2A, CN
Backing Polyimide
Element Special alloy foil
Strain limit 1% (10000 x 10-6 strain)
Fatigue life at room temperature 1 x 106 (±1500 x 10-6 strain)
  • High and low temperature Use

    Gauge pattern Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance
    (Ω)
    Single element
    (G.F. 2.1 approx.)
    cfla_111
    CEF-1-11
    CEFLA-1-11
    CEFLA-1-17
    CEFLA-1-23
    1 0.5 4 2.2 120
    CEFLA-3-11
    CEFLA-3-17
    CEFLA-3-23
    3 0.6 6.9 2.8 120
    CEFLA-6-11
    CEFLA-6-17
    CEFLA-6-23
    6 1.0 10.6 3.1 120

    Each package contains 10 gauges.

  • Leadwire-integrated CEF series (made-to-order)

    Purpose Lead wires Lead wire symbol Operating temperature range(℃) Gauge type exampled
    High and low temperature 3-strand twisted FEP wire 6FA♦LT -269 to+200 CEFLA-1-11-6FA3LT-F
    3-strand twisted FEP single-core wire 6FB♦LT CEFLA-1-11-6FB3LT-F
    3-strand twisted PTFE wire 4FA♦LT -269 to+260 CEFLA-1-11-4FA3LT-F
    3-strand twisted PTFE single-core wire 4FB♦LT CEFLA-1-11-4FB3LT-F

    *  "♦" indicates lead wire length

Pi-shape Displacement Transducer

PI Pi-shape Displacement Transducer  ±2mm to ±5mmCEロゴ

The PI displacement transducer has a simple structure; which considered an arch-shaped spring plate with strain gauges mounted on it.. Six models designed for gauge lengths of 50 mm to 300 mm are available. This transducer is used to measure the crack opening displacement occurring within each gauge length on the surface of concrete or to measure the displacement of various structures.

PI Pi-shape Displacement Transducer
Features
  • Simple shape
  • Stable measurement possible
  • Versatile gauge lengths
  • Easy handling
  • Specifications

    Type

    Gauge Length
    (mm)

    Capacity Rated output Sensitivity
    (x 10-6 strain/mm)
    Non-linearity Temperature range
    PI-2  50,100,
    150,200,
    250,300
    ±2mm Approx. 2mV/V
    (4000 x 10-6 strain)
    Approx. 2000 0.5%RO 0 to +40℃
    PI-5  ±5mm Approx. 2.5mV/V
    (5000 x 10-6 strain)
    Approx. 1000

    Output polarity

    img-trout-07

    Measurement moves in the plus direction with regard to an increase of the opening.