KCE-NA Center-hole type Compression Load Cell 500kN to 2MN
The KCE-NA Load Cell is a center-hole-type load cell designed to use in tension measurement of anchoring strand. It can deliver stable measurement performance under somewhat eccentric load. An extra model with built-in temperature sensor is available.
Protection ratings : IP 67 equivalent.
- Features
- Splash-proof structure
- Small effect of eccentric load
-
Specifications
Type Capacity Rated output Non-linearity Temperature
rangeKCE-500KNA 500 kN 1.25 mV/V
(2500x10-6 strain) ±10 %0.5 %RO -20 to +70 ℃ KCE-1MNA 1 MN KCE-1.5MNA 1.5 MN KCE-2MNA 2 MN Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
More Information
KCH-NA Center-hole type Compression Load Cell 500kN to 2MN
The KCH-NA Load Cell is a center-hole-type load cell designed to use in tension measurement of anchoring strand. It can deliver stable measurement performance under somewhat eccentric load.
Protection ratings : IP 68 equivalent
- Features
- Protection ratings IP 68 equivalent
- Small effect of eccentric load
-
Specifications
Type Capacity Rated output Non-
linearityTemperature
rangeKCH-500KNA 500kN 1.25mV/V
(2500×10-6strain)±10%0.5%RO -20 to +70 °C KCH-1MNA 1MN KCH-1.5MNA 1.5MN KCH-2MNA 2MN Output polarity (caution)
Output polarity of this load cell changes to plus polarity with regard to increased compressing force.
More Information
KCK-NA Center-hole type Compression Load Cell 500kN to 1MN
The KCK-NA load cell is a center-hole type load cell designed to use in tension measurement of anchoring strand. It is suited to lift-off testing and monitoring of existing anchors.
This system was developed as a joint research project, “development of a new-type anchor load cell allowing easy installation to /replacement of an already installed anchor” (Nov. 2006 to Sep. 2009), by the Public Works Research Institute and 8 private companies.
Protection ratings : IP 67 equivalent
- Features
- Aki-Mos (installed anchor tensile force monitoring system) load cell
- Light weight
- Low Profile
-
Specifications
Type Capacity Rated output Non-
linearityTemperature
rangeKCK-500KNA 500 kN 1.25m V/V
(2500x10-6 strain)±10 %1% RO -30 to +70 °C KCK-1MNA 1 MN 1.4m V/V
(2800x10-6 strain)±10 %Output polarity (caution)
Output polarity of this load cell changes to plus polarity with regard to increased compressing force.
More Information
KCM-NA Center-hole type Compression Load Cell 10kN to 5MN
The KCM-NA Load Cell is a center-hole-type load cell with strain gauges mounted on a cylindrical strain sensing element. It is used to measure prestress or tension force on ground anchors, pullout testing and measuring axial force on tie rods. The model is especially well suited for measuring on site.
Protection ratings : IP 67 equivalent
- Features
- Splash-proof structure
- Small, Easy handling
-
Specifications
Type Capacity Rated output Non-linearity Temperature
rangeKCM-10KNA 10 kN 1.5 mV/V
(3000x10-6 strain) ±20 %0.5 %RO -20 to +70 ℃ KCM-20KNA 20 kN KCM-50KNA 50 kN 1.5 mV/V
(3000x10-6 strain) ±10 %KCM-100KNA 100 kN KCM-200KNA 200 kN KCM-300KNA 300 kN KCM-500KNA 500 kN KCM-1MNA 1 MN KCM-2MNA 2 MN 1% RO KCM-3MNA 3 MN KCM-5MNA 5 MN Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
More Information
CLC-NA Center-hole type Compression Load Cell 50kN to 5MN
The CLC-NA Load Cell is a center-hole-type load cell with strain gauges mounted on a cylindrical strain sensing element. It is used for pullout tests on anchors or laboratory experiments.
Protection ratings : IP 65 equivalent
- Features
- High Precision
- Small, Easy handling
-
Specifications
Type Capacity Rated output Non-linearity Temperature
rangeCLC-50KNA 50 kN 1.5 mV/V
(3000x10-6 strain) ±0.5 %0.3 %RO -20 to +70 ℃ CLC-100KNA 100 kN CLC-200KNA 200 kN CLC-300KNA 300 kN CLC-500KNA 500 kN 0.5 %RO CLC-1MNA 1 MN CLC-2MNA 2 MN CLC-3MNA 3 MN CLC-5MNA 5 MN Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
More Information
KCC-NA Center-hole type Compression Load Cell 200kN to 1MN
The KCC-NA Load Cell is a center-hole-type load cell with flanges. The large diameter of its center hole makes this load cell suitable for use in almost all anchoring methods. It can deliver stable measurement performance under a relatively high eccentric load.
Protection ratings : IP 67 equivalent
- Features
- Large center hole diameter
- Top and bottom flanges attached
- Small effect of eccentric load
- Splash-proof structure
-
Specifications
Type Capacity Rated output Non-linearity Temperature
rangeKCC-200KNA 200 kN 1mV/V
(2000x10-6 strain) ±10 %1 %RO -20 to +70 ℃ KCC-500KNA 500 kN KCC-1MNA 1 MN Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
More Information
KCG-NA Center-hole type Compression Load Cell 200kN
Small and inexpensive center-hole load cell that can be installed at the anchor position of strand such as in bridge.
Protection ratings : IP 67 equivalent
- Features
- Small, Lightweight
- High output,High precision, Low price
- Watrerproof and mechanical protective coating
- Easy handling
-
Specifications
Type Capacity Rated output Non-linearity Temperature
rangeKCG-200KNA 200 kN 2.25 mV/V
(4500x10-6 strain) ±10 %0.5 %RO -30 to +70 ℃ Output polarity
Measurement moves in the minus direction with regard to increased compressing force.